TA-Smart Fail-safe
2-way control valve with uniquely shaped EQM characteristics with flow, temperature, power measurement capabilities and electronic fail-safe function
The ultrasonic flow measurement technology combined with unique actuation algorithms capabilities provide best-in-class control performances. The TA-Smart Fail-safe controls can be set to flow or power, giving high on-site flexibility and providing highly effective comfort in heating and cooling applications. Its compact arrangement and simple set-up reduces installation and commissioning time.
Features and Benefits
Applications
Heating and cooling systems.
Functions
Control (flow, power, position)
Pre-setting (max./min. flow, max. power, max./min. position)
Reading (flow, power, energy, supply/return temperature, ΔT, position)
Change-over
Delayed start-up
ΔT and temperature return limitation
Diagnostic/Logging
Electronic fail-safe function
Error safe position
Manual override
Mode, status and position indication
Valve blockage protection
Valve clogging detection
Supply voltage [V]
24 VAC/VDC ±15%. Frequency 50/60 Hz ±3 Hz
Ingress protection
IP54 (according to EN 60529)
Media
Water or neutral fluids, water-glycol mixtures (0-57%).
Wireless
Thread
Bluetooth Low Energy (BLE)
Temperature
Max. working temperature: 110°C
Min. working temperature: -10°C
Operating environment: 0°C – +50°C (5-95%RH, non-condensing)
Storage environment: -20°C – +70°C (5-95%RH, non-condensing)
Input signal
By BACnet/Modbus or Analog signal. Analog in VDC or mA, selectable by jumper in the SmartBox;
Proportional dual-range (for change-over): 0-4.5 / 5.5-10 VDC. 2-5.5 / 6.5-10 VDC. 0-3.3 / 6.7-10 VDC. 2-4.7 / 7.3-10 VDC. 0-9 / 11-20 mA. 4-11 / 13-20 mA.
0(2)-10 VDC, Ri 47 kΩ.
0(4)-20 mA R i 500 Ω.
Adjustable sensitivity 0.1-0.5 VDC; 0.33 Hz low pass filter.
Default setting: Proportional 0-10 VDC
Proportional: 0-10, 10-0, 2-10 or 10-2 VDC; 0-20, 20-0, 4-20 or 20-4 mA
Proportional split-range: 0-5, 5-0, 5-10 or 10-5 VDC; 0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC; 2-6, 6-2, 6-10 or 10-6 VDC; 0-10, 10-0, 10-20 or 20-10 mA; 4-12, 12-4, 12-20 or 20-12 mA
Leakage rate
DN 15-50: Leakage rate < 0.01% of q, nom with correct flow direction (Class IV according to EN 60534-4)
DN 65-125: Tight sealing with correct flow direction (Class V according to EN 60534-4)
Output signal
0(2)-10 VDC, max. 8 mA, min. 1.25 kΩ.
BACnet/Modbus
Pressure class [PN]
DN 15-50: PN 25
DN 65-125: PN 16, PN 25
Characteristics
Settable: Stepless between EQM 0.25 and inverted EQM 0.25.
Pipe connection
DN 15-50: External thread according to ISO 228.
DN 65-125: Flanges according to EN-1092-2, type 21. Face to face length according to EN 558, series 1.
Protection class
(according to EN 61140)
Surface treatment
DN 15-50: Non treated
DN 65-125: Electrophoretic painting
Flow control accuracy
±10% from 0.5% to 4% of qnom
±5% from 4% to 100% of qnom
Temperature sensor cable
10 m halogen free cable on request.
DN 15-50: 3 m halogen free
DN 65-125: 5 m halogen free
Certifications and directives
EMC-D. 2014/30/EU: EN 60730-1, -2-14.
PED: 2014/68/EU
Product standards EN 60730-x.
Material
Flow range
Power consumption
Measurement accuracy
Differential pressure (ΔpV)
Art. No. |
---|